ActiveBOM is a powerful Bill of Materials (BOM) management editor that combines comprehensive BOM management tools with Altium's powerful part-information aggregation technologies, helping you manage the component selection challenge and providing you with instant visibility to component availability and potential supply chain risks.
Setting Up an ActiveBOM Document
To create a new ActiveBOM document for your design project, right-click the project's entry in the Projects panel and select Add New to Project » ActiveBOM command from the context menu. The ActiveBOM document listing all of the components in the design will open in the design space.
Options for an ActiveBOM document are configured in the Properties panel. The main options are configured on the General tab of the panel:
- Production quantity and preferred currency (the General region) – define the number of boards to be built (Production Quantity) and the preferred Currency to display component prices. The production quantity value is used during supply chain searching to check component availability from the suppliers.
-
Supply chain options (the Supply Chain region) – define the number of manufacturer parts you would like to be located for each BOM item (Solutions per Item) and the number of suppliers you would like to be located for each manufacturer part (Suppliers per Solution).
From here, you can also exclude all supplier part numbers considered invalid (no stock, no prices available, or out-of-date price/availability – Exclude Invalid SPNs) and define the overall list of suppliers for the ActiveBom document (Favorite Suppliers List).
The BOM item list of the ActiveBOM document shows both item details and supply chain information (for the entered numbers of manufacturers and suppliers).
Data columns shown in the BOM item list of the ActiveBOM document are configured on the Columns tab of the Properties panel. Use the visibility icons in the column list to define their visibility.
Line numbers of BOM items are defined in the Line # column. You can automatically set the line numbers by clicking the button at the top of the ActiveBOM document.
Working with Solutions
Each manufacturer part for a BOM item in the ActiveBOM document and available suppliers of this manufacturer part is referred to as a Solution for this item. In the row for each solution, the manufacturer part is detailed on the left, with each available supplier detailed on a separate color-coded tile.
For a component placed in your design from the Workspace Library, each Part Choice defined for this component automatically presents as a solution in the ActiveBOM document. You can edit part choices for the selected Workspace Library component by clicking the Add Solution button at the top of the solution region of the ActiveBOM document and selecting the Edit Part Choices in Library command from the menu that appears.
For components with multiple solutions, the solutions are automatically ranked from highest to lowest based on the part's availability, price and manufacturer lifecycle state. If you prefer to use a lower-ranked solution, you can override the automatic ranking by defining a user rank using the star feature. For Workspace Library components, you can also rank its part choices, and this ranking will be reflected in the ActiveBOM document.
Verifying the BOM
Each BOM item is checked for violations, and its status is displayed in the BOM status column, which is always visible on the right side of the BOM items list. An icon indicates the item's status: clear (no issues), warning, error, or fatal error. Hover the cursor over an icon to see details about issues detected for this item.
The list of violations currently present in the ActiveBOM document and the number of items offended by each violation type is displayed in the BOM Checks region of the General tab of the Properties panel.
Click the button at the bottom of the region to access the BOM Checks dialog from where you can configure the severity level (report mode) of each BOM check.